Showing all 2 results

TruckTank 425 L mobile AdBlue tank
425 LAdBlue12 V
TruckTank 425 L mobile AdBlue tank

TruckTank 425 L mobile AdBlue tank

  • 425 L
  • Mobile
  • Single-wall
Price on request

TruckTank 425 L mobile AdBlue tank with a capacity of 425 L from the JFC Polska product range. Mobile AdBlue storage with a reinforced ribbed housing that limits movement of the liquid during transport. External dimensions: 120 x 80 x 77 cm. Version: BASIC. Before ordering, we check together which version and equipment suit your way of working.

TruckTank Combi 400 L mobile AdBlue tank
400 LAdBlue12 V
TruckTank Combi 400 L mobile AdBlue tank

TruckTank Combi 400 L mobile AdBlue tank

  • 400 L
  • Mobile
  • Single-wall
Price on request

TruckTank Combi 400 L mobile AdBlue tank with a capacity of 400 L from the JFC Polska product range. Mobile AdBlue storage with a reinforced ribbed housing that limits movement of the liquid during transport. External dimensions: 122 x 80 x 81 cm. Version: Two-compartment version. Before ordering, we check together which version and equipment suit your way of working.

Selection

How to choose

First determine the scale of consumption and the way you will use it. For individual vehicles or machines in the field, a mobile unit is sufficient. For a permanent dispensing point in a workshop or yard, a stationary version is more suitable, where you also choose between single-wall and double-wall construction — the latter does not need a separate spill containment tray. For larger vehicle fleets and frequent refuelling, consider a filling station, which is designed for higher flow rates and longer use. Also check the available power supply and whether you need heating of the dispensing section for winter operation.

1 Required capacity How much AdBlue you need to hold in stock between two deliveries.
2 Type of version Stationary installation, mobile version or filling station.
3 Construction Single-wall or double-wall version depending on the requirements of the installation site.
4 Dispensing and power supply Available power supply and requirements for dispensing equipment.
  • Expert help with selectionWe help you choose a solution to suit your building and use.
  • Technical documentationInstructions, certificates and technical data are available.
  • Configuration to your needsWe prepare the quotation based on the selected version and optional equipment.
  • Pre-purchase supportWe help with technical questions and preparing the quotation.

Which solution is right for you?

Four questions that tell you the most about what you need.

  1. 1Required capacity

    How much AdBlue you need to hold in stock between two deliveries.

  2. 2Type of version

    Stationary installation, mobile version or filling station.

  3. 3Construction

    Single-wall or double-wall version depending on the requirements of the installation site.

  4. 4Dispensing and power supply

    Available power supply and requirements for dispensing equipment.

What distinguishes this range

  • Components selected specifically for AdBlue and resistant to urea
  • A closed system reduces the risk of contaminating the liquid
  • Stationary, mobile and station versions cover different consumption levels
  • Option of a double-wall version for installation without an additional spill containment tray

How to choose

First determine the scale of consumption and the way you will use it. For individual vehicles or machines in the field, a mobile unit is sufficient. For a permanent dispensing point in a workshop or yard, a stationary version is more suitable, where you also choose between single-wall and double-wall construction — the latter does not need a separate spill containment tray. For larger vehicle fleets and frequent refuelling, consider a filling station, which is designed for higher flow rates and longer use. Also check the available power supply and whether you need heating of the dispensing section for winter operation.

Frequently asked questions

Why does AdBlue need a special tank?

AdBlue is an aqueous urea solution that is aggressive towards some metals and sensitive to impurities. The tank and dispensing equipment must be made of materials adapted to this.

What is the difference between single-wall and double-wall versions?

A double-wall tank has an inner and an outer shell with an interspace that retains the liquid in the event of a leak. A single-wall tank is simpler and, as a rule, requires a suitably prepared installation site.

When does a filling station make sense?

When you have several vehicles or machines and frequent refuelling. The station is designed for higher flow rates and continuous operation.

Can I combine diesel and AdBlue in one unit?

Yes, the range includes combined mobile units with separate compartments for diesel and AdBlue.

Can you prepare a configuration to suit my use?

Yes. Each product page has a configurator in which you select optional equipment. The selected configuration is automatically attached to the enquiry so that we can prepare a suitable quotation.

Where can I find the technical documentation?

Documentation is available on request. Use the documentation button on the product page or send an enquiry stating which data you need.

How do I get a quotation?

Select the product and, if needed, optional equipment, then send an enquiry. In the form, indicate whether you want a quotation, advice or a call. We prepare the quotation based on the selected version.

Not sure which solution is right?

For help choosing an AdBlue tank version, send us an enquiry.